Sapphire 600Sapphire 600® Plus fully automated 600 tests per hour compact Clinical Analyser. Providing up 600 tests per hour including ISE with on board laundry bar-coded reagents and samples.

Features

  • 600 tests/hour, including ISE
  • Auto-rerun with Auto-dilution
  • Sample Pre-dilution
  • 24 Hour Reagent Colling at 10°C Below Ambient
  • Individual Probes for Sample, R1 and R2
  • On-board Cuvette Washing
  • Long Life Individual Cuvettes
  • Barcoded Reagent and Samples
  • Primary Tubes 5,7,10 ml
  • 80 Position Sample Tray
  • 50 Position Reagent Carousel
  • 60 Position Cuvette Rotor
  • 2 Position Stirrer
  • Vertical Obstruction Detection
  • Weight Based Level Sensing for Water Cleaning Solution and Waste
  • Separation of Bio-Hazardous Waste
  • Result Re-calculation Facility
  • Storage of Reagent Blank OD and Calibration OD


Measurement

System Discrete, single line random access, multi-test analysis
Number of tests on board 50 items max.
Throughput Up to 360 tests / hour  and 600 tests per hour with ISE
Analytical method End point, Kinetic Initial rate ISE
Calibration curve Linear, Non-Linear, Multi-Point

 

Sample Handling

Contents of test Clinical chemistry, Homogeneous, immuno-assay, TDM, DOA
Sample container Primary Tubes 5,7,10ml + Sample Cups
Sample number 80 samples / tray
Sample volume 3-50µ| (0.1µ| steps)
Automatic dilution Dilution ration: 10 - 100
Stat sample measurement Immediate Access and Execution
Sample Identification Position ID, Bar-code ID (option)

 

Reagent Handling

Reagent tray 50 positions cooled
Reagent bottle 20ml 50ml
Reagent volume 5-300µ| (1µ| step)
Reagent cooling temp Ambient -10°C
Residual volume info. Level Detection System
Reagent ID
Barcode Positive ID
Tray exchange Continuous

 

Reaction

Curvette material Glass
Reaction liquid volume 250µ| min.
Reaction temperature 37°C ± 0.1°C
Wavelength (nm) Mono + Bio-Chromatic with multi-wavelength
Diffraction Grating - 12 Wavelengths
340 / 376 / 415 / 450 / 505 / 546 / 570 / 600 / 660 / 700 / 750
Light Source Tungsten halogen lamp
Linear Range OD 0-2.5
Cuvette Washing By the automatic washing system
Water Consumption Max 5 litres / hour

 

User Interface

Run Monitor Operation status on screen
Quality Control Levy-Jennings
Data Storage Capacity Unlimited number of methods
Data files for samples, controls and calibrators
Printer External
Power Supply AC110-220V 50/60Hz (Auto Detecting)
Environmental 18~28°C 10-90% relative humidity
Dimensions 800 (W) x 450 (H) x 580 (D) mm
Weight Approx. 150kg incl CPU
Data Calibration curves for unlimited number of calibrators
Stats input

 

Test Items

Clinical Chemistry ACP
AMY-P
AST-M
CK
ALB
CRE
FRA
HB
TP
UA
ACE
ALP
CO2
yGT
ALC
CL
FE
IP
T-BIL
LIPASE
AM
ALT
CHE
HBDH
CA
CU
GLU
LDL-C
TG
UREA
AMY
AST
CKMB
LDH
CHO
D-BIL
HDL-C
MG
µ-TP
ZN
 
Immuno-Assay Ig-G
C4
Tf
ApoB
Fer
Ig-A
CRP
ß2-M
ApoC-11
MA
Ig-M
ASO
ApoA-1
ApoC-III
CEA
C3
RF
ApoA-11
ApoE
LP(a)
 
TDM PRM
PB
PHT
CBZ
VAP
DIG
TEHO
 
Electrolytes Na K Cl  
 
DOA Amphetamines
Cocaine Metabolite
Methaqualone
Barbituates
Cotinine
Opiates
Benodiazepine
Ethyl Alcohol
Phencyclidine
Cannabinoid THC
Methadone
Propoxphene
 
Under Development CEA
Myoglobin
D-Dimer
PSA
HbAlc
Troponin
Homocysteine

ORDERING INFORMATION
Catalogue Numbers:
ADS600 Sapphire 600+ without PC
ADS600/ISE Sapphire 600+ with ISE without PC


Download PDF All the above reported features can be changed without prior notice
Complying with EMC EEC Directives
Back To Top