System General
| System Type | Fully Automated, Discrete, Random access, Patient Prioritized, Clinical Chemistry Analyzer |
| Throughput | 800 Tests / Hour Fixed 400 Tests / Hour for Photometric Test |
| Assay Item | Maximum 88 Photometric Tests, plus 3 ISE |
| Water Consumption | 25 Lt / Hour |
| Analytical Method | End Point, End Point 2, Rate, 2 Point Rate, Twin Assay |
Sample Handling
| Contents of test | Clinical Chemistry, ITA, TDM, DOA |
| Sample container | Primary tubes of 5, 7 & sample cups |
| Sample Tray | 115 Positions, including Stat, calibrator and control positions |
| Sample volume | 2 - 35µl (adjustable in 0.1 µl step) |
| Sample Barcode | Support Codabar, 12 o f5, Code 128, Code 39, Code 93, UPC / EAN |
| Sample Probe | Temperature controlled, Level detection, Clot detection and Obstacle detection |
| Stat Sampling | Immediate access |
| Sample Dilution | On board 1:2 - 170 times |
Reagent Handling
| Reagent tray | 2 x 45 positions with cooling |
| Reagent bottle | 70ml, 20ml |
| Reagent volume (µl) | 20 - 350µl (adjustable in 1 µl step) |
| Reagent cooling | 5 - 15°C, 24 hours Standby cooling |
| Reagent Barcode | Support Codabar, 12 of 5, Code 128, Code 39 |
| Reagent Probe | Temperature controlled, Level detection, Clot detection and Obstacle detection |
Reaction
| Reaction Tray | 120 reusable PMMA cuvettes |
| Reaction Volume (µl) | 150 - 450 µl |
| Photometry Optics (nm) | Grating photometry mono/bi-chromatic measurement 12 Wavelengths: 340 / 380 / 405 / 450 / 480 / 505 / 546 / 570 / 600 / 660 / 700 / 750 |
| Absorbance Range | 0 - 3.3ABS |
| Light Source | Halogen lamp (20W/12V), Long life over 2000 Hours |
| Optical Path | 6mm |
| Washing Unit | 7 Stops 11 Steps automatic warm water laundry unit |
| Stirrer | 2 Separated Stirrers |
User Interface
| Display Resolution | 1024 x 768 |
| Software | Based on Windows XP or higher |
| Auxiliary Data | Non limit |
| Interface | RS-232 C port for Bi-directional Communication |
| Run Monitor | Operation status on screen |
| Reaction Curve | Review whole reaction process |
| Printer | External |
| Calibration | Linear (One, Two and Multi Point), Factor, and Non-linear Multi Point |
| Control | Levy-Jennings, Daily and Monthly QC Statics |
| Power Supply | 220 ± 22 V AC (or 110 ± 3 V AC, optional), 2000 VA, 50 ± 1 Hz |
| Environmental | 15 - 30, 10 - 90% relative humidity |
| Dimensions | 1060 (W) x 790 (D) x 1150 (H) mm |
| Weight | 330kg |
ORDERING INFORMATION
Catalogue Numbers:
ADS800 Sapphire 800 Automated Clinical Chemistry Analyser, Without PC
ADS800/ISE Sapphire 800 Automated Clinical Chemistry Analyser, With ISE, Without PC
![]() |
All the above reported features can be changed without prior notice Complying with EMC EEC Directives |